EAR PIERCING INSTRUCTIONS-
Replacing the stud Adapter Using
the Studex Adapter Clip
Please read these instructions carefully before using
the Adapter Clip to remove or install the stud adapter
in order to prevent damage to the adapter, the clip
or the instrument.
Removing the Stud Adapter
1. Make sure the instrument is uncocked.
2. Place the empty Adapter Clip over the plunger as
shown in Figure 5-1.
3. Pull the plunger knob back firmly (Fig. 5-2). The
stud adapter will snap out of the plunger shaft automatically.
4. Lift the Adapter Clip off the instrument. The stud
adapter will remain in the
Adapter Clip (Fig. 5-3).
HINT: If you are using the Clips to store the adapters,
be sure to match the color of the Clip to the color
of the collar on the adapter. This will make identification
on the proper stud adapter easier for the next piercing
operation.
Installing the Stud Adapter
1.Cock the Instrument
2. Snap the proper stud adapter into the Adapter Clip
as shown in (Fig.5-4).

3. Place the Adapter Clip (with the stud adapter in
it) over the plunger as shown in (Fig.5-5).
4. While holding the plunger knob firmly to keep the
plunger from snapping forward, pull the trigger to release
the plunger, and gently slide the plunger to the fully
forward position (Fig.5-6). (DO NOT simply pull the
trigger and ´fire´the plunger, as damage
to the adapter, clip or the instrument could result
when the plunger snaps forward.)
5. Once the plunger shaft is fully forward, lift off
the Adapter Clip (Fig.5-7)
6. Cock the instrument and press the stud adapter firmly
to make sure it is fully seated in the shaft (Fig.5-8).
The adapter will ´click´ when it is properly
seated.

Cleaning the Instrument
1. Before and after each piercing, throughly cleanse
the entire area of the clasp retainer (see Fig.6) by
wiping with a cotton ball or swab moistened with MediSept
Ear Care Solution or alcohol.

|